10 SETUP MODE The advanced Setup Mode allows you to customize the following meter preferences and defaults: Real Time Clock Decimal Type
11 SETUP MODE Real Time Clock 1. Enter the clock function from Setup Mode (see page 10). “dAtE” appears on the LCD. 2. Press ENTER. The year wil
12 SETUP MODE Auto Power Off The meter automatically turns off after 10 minutes of inactivity, however this function can be disabled. 1. Enter
13 SETUP MODE 2. Press ▲ or ▼ to select C (degrees Celcius) or F (degrees Fahrenheit). Press ENTER to save the selection. Sampling Time The samp
14 MEASUREMENT PROCEDURES Turning the Unit On/Off 1. Press POWER to turn the meter on. 2. Press and hold POWER for 2 seconds to turn the meter of
15 MEASUREMENT PROCEDURES When the probe is not used, the sensor cover should be in the up position. Probe Handle 1. Press POWER to turn the meter on
16 MEASUREMENT PROCEDURES Type K/J Thermometer 1. Press POWER to turn the meter on. 2. Press and hold FUNC to cycle through the options until “tP”
17 MEASUREMENT PROCEDURES Maximum and Minimum To record maximum and minimum readings: 1. When measuring any parameter, press REC to begin recording
18 MEASUREMENT PROCEDURES Backlight 1. The backlight turns on automatically when the meter is turned on. 2. Press to turn the backlight off
19 DATALOGGER Preparing the Datalogger 1. Insert the SD card into the SD card socket on the bottom of the meter, ensuring that the front of t
2 Hot Wire Anemometer SD Card Datalogger 850024 Copyright ©2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA 7720 E. Redfi
20 DATALOGGER Note… To enable/disable the touch-tone feature see page 12. Manual Datalogging 1. Set the sampling time to 0 seconds (see page 13).
21 DATALOGGER SD Card Data Structure 1. The first time a SD card is used in this meter, a folder AMA01 will be generated. 2. If the datalogger is b
22 BATTERY REPLACEMENT This meter uses six AA (1.5 V, UM3) batteries. When the low battery indicator appears on the LCD, battery replac
23 PC CONNECTION To save data from the SD card to a PC (using Excel software): 1. After datalogging is complete, remove the SD card from the meter’
24 PC CONNECTION Excel Data Screen RS232 PC Serial Interface This meter has a RS232 PC serial interface via a 3.5 mm terminal. The data
25 The 16 digit data stream will display in the following format: D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the fol
26 PC CONNECTION RS232 Format: 9600, N, 8, 1 D11 & D12 Annunciator for Display °C = 01 Knot = 09 mile/h = 12 °F = 02 Km/h = 10 m/S =
27 OPTIONAL ACCESSORIES 800060~77 Type K Thermocouple Probes 840057 RS232 Computer Cable 840059 2GB SD Card 840090 Water Resistant
28 SPECIFICATIONS General Circuit Custom one-chip of microprocessor LSI circuit Display LCD size: 52 mm x 38 mm Backlight function Measurement Unit
29 SPECIFICATIONS Operating Humidity < 85% RH Alkaline or heavy duty DC 1.5 V battery (UM3, AA) x 6 pieces DC 9V adapter input (AC/DC power adap
3 TABLE OF CONTENTS INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 Air Velocity Air Temperature Range 0 ~ 50°C (32 ~ 122°F) Resolution Accuracy ± 0.8°C (± 1.5°F) 0.1°C (0.1°F) Measurement Range Resolution Accura
31 Type K/J Thermometer SPECIFICATIONS Sensor Type Range Resolution Accuracy -50.0 ~ 1300.0°C -50.1 ~ -100.0°C 0.1°C ± (0.4% readin
32 WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purch
4 INTRODUCTION The Sper Scientific Hot Wire Anemometer SD Card Datalogger (Model 850024) is an extremely accurate meter with fast response times th
5 Reads air velocity and temperature and functions as a Type K/J thermometer Telescopic Hot Wire Probe provides high accuracy in high and low v
6 MATERIALS SUPPLIED Meter Telescopic Hot Wire Probe SD Card 6 AA Batteries Instruction Manual Hard Carrying Case POWER SUPPLY Thi
7 KEYPAD LCD Display POWER (ESC, Backlight) SET (▼, TIME CHECK) LOGGER (▲, SAMPLING TIME CHECK) FUNCTION/ HOLD/NEXT REC/ENTER/UNIT
8 METER COMPONENTS Anemometer Probe Input Socket SD Card Socket RESET Type K/J Thermometer Socket Top of Meter Bottom of Meter Side of Met
9 METER COMPONENTS Tripod Mounting Screw Battery Cover Screws Battery Compartment/ Cover Stand Back of Meter Sensing Head Telescope Probe Probe Pl
Comentarios a estos manuales